Armenian Journal of Physics=Ֆիզիկայի հայկական հանդես
The interaction of the AREAL photoelectron gun beam with the matter was simulated applying particle tracking software. The produced secondary particle fluxes produced at the certain places of interest within the AREAL facility experimental hall was calculated utilizing the data obtained by electron beam diagnostic system; particularly Faraday Cups (FC) and YAG screen stations. Absorbed dose rate has been measured by high precision ion chamber dosimeter capable to measure radiation produced by high frequency pulsed source. The comparison of the simulation and dose measurement results allows validation of the calculation methods and beam diagnostic data. Particularly ion chamber measurement of the dose creates opportunity to estimate the beam energy spread more accurately.
oai:arar.sci.am:23490
ՀՀ ԳԱԱ Հիմնարար գիտական գրադարան
Dec 13, 2023
Feb 27, 2020
25
https://arar.sci.am/publication/26252
Հրատարակութեան անունը | Թուական |
---|---|
Interaction of the 5 MeV electron beam with the matter in the AREAL photoelectron gun facility experimental hall | Dec 13, 2023 |
H. Tamoyan G. Zanyan H. Davtyan
M. V. Navasardyan K. Y. Muradyan K. V. Kutsenko
G. H. Shahkhatuni V. M. Aroutiounian V. M. Arakelyan M. S. Aleksanyan G. E. Shahnazaryan